PROGRAMMA DI RICERCA 2005

italiano - english
Programmi di ricerca simili:
Classificazione scientifico-disciplinare
Classificazione brevettuale
Classificazione geografica
Bibliografia
1. A.B. Otis, C.B. McKerrow, R.A. Bartlett, J. Mead, M.B. McIlroy, N.J. Selverstone, P.Radford, "Mechanical factors in distribution of pulmonary ventilation", J. Appl. Physiol., vol.8 (1956), 427-443.
2. K.R. Lutchen, F.P. Primiano, G.M. Saidel, "A nonlinear model combining pulmonary mechanics and gas concentration dynamics", IEEE Trans. Biomed. Eng., vol.29 (1982), 629-641.
3. Barbini P., "Non-linear model of the mechanics of breathing applied to the use and design of ventilators", J. Biomed. Eng., Vol. 4, pp. 294-304, 1982.
4. P. Valta, Corbeil, C.; Lavoie, A.; Campodonico, R.; Koulouris, N.; Chasse, M.; Braidy, J.; Milic-Emili, J. Detection of expiratory flow limitation during mechanical ventilation. Am. J. Respir. Crit. Care Med., Nov. 1994, vol. 150, no. 5 Pt 1, p. 1311-1317.
5. V.M. Ranieri, M. Dambrosio, and N. Brienza. Intrinsec PEEP and cardiopulmonary interaction in patients with COPD and acute ventilatory failure. Eur. Respir. J. 9:1283–1292, 1996.
6. A. Rossi, A. Ganassini, G. Polese, and V. Grassi. Pulmonary hyperinflation and ventilator-dependent patients. Eur. Respir. J. 10:1663–1674, 1997.
7. Avanzolini G., P. Barbini, F. Bernardi, G. Cevenini, L. Chiari, G. Gnudi, M.R. Massai, "A numerical simulator of the respiratory mechanics in artificially-ventilated patients", Med. Biol. Eng. Comput., Vol. 37, Suppl. 2, pp. 1192-1193, 1999.
8. S. Khirani, Biot L, Eberhard A, Baconnier P. Positive end expiratory pressure and expiratory flow limitation: a model study. Acta Biotheor. 2001;49:277-90.
9. M. S. Lourens, B. V. D. Berg, H. C. Hoogsteden, and J. M. Bogaard, “Detection of flow limitation in mechanically ventilated patients,” Intensive Care Med., vol. 27, no. 8, pp. 1312-1320, Aug. 2001.
10. Avanzolini G., P. Barbini, F. Bernardi, G. Cevenini, G. Gnudi, "Role of the mechanical properties of tracheobronchial airways in determiningthe respiratory resistance time course", Ann. Biomed. Eng., Vol. 29, pp. 575-586, 2001.
11. Barbini P., G. Cevenini, F. Bernardi, M.R. Massai, G. Gnudi, G. Avanzolini, "Effects of compliant intermediate airways on total respiratory resistance and elastance in mechanical ventilation", Med. Eng. Phys., Vol. 23, pp. 185-194, 2001.
12. Nucci G., S. Tessarin, C. Cobelli, "A morphometric model of lung mechanics for time-domain analysis of alveolar pressures during mechanical ventilation", Ann. Biomed. Eng., Vol. 30, pp. 537-545, 2002.
13. Nucci G., B. Suki, K.R. Lutchen, "Modeling airflow-related shear stress during heterogeneous constriction and mechanical ventilation", J. Appl. Physiol., Vol. 95, pp. 348-356, 2003.
14. Barbini P., G. Cevenini, G. Avanzolini, (2003). "Nonlinear mechanisms determining expiratory flow limitation in mechanical ventilation: A model-based interpretation", Ann. Biomed. Eng., Vol. 31, pp. 908-916, 2003.
15. A.G. Polak and K.R. Lutchen. Computational model for forced expiration from asymmetric normal lungs. Ann. Biomed. Eng. 31:891-907, 2003.
16. P. Barbini, C. Brighenti, G. Cevenini, G. Gnudi, "A dynamic morphometric model of the normal lung for studying expiratory flow limitation in mechanical ventilation, Ann. Biomed. Eng., Vol. 33, pp. 516-528, 2005.
17. Avanzolini G., P. Barbini, "Comments on estimating respiratory mechanical parameters in parallel compartment models", IEEE Trans. Biomed. Eng., Vol. 29, pp. 772-774, 1982.
18. Avanzolini G., P. Barbini, "A versatile identification method applied to analysis of respiratory mechanics", IEEE Trans. Biomed. Eng., Vol. 31, pp. 520-526, 1984.
19. Avanzolini G., P. Barbini, "Sensitivity analysis for an improved estimation of respiratory mechanics parameters", J. Biomed. Eng., Vol. 6, pp. 189-194, 1984.
20. Avanzolini G., P. Barbini, "A comparative evaluation of three on-line identification methods for a respiratory mechanical model", IEEE Trans. Biomed. Eng., Vol. 32, pp. 957-963, 1985.
21. Avanzolini G., P. Barbini, "Influence of experimental conditions on parameter estimation for breathing mechanics: a sensitivity analysis approach", Med. Biol. Eng. Comput., Vol. 25, pp. 305-310, 1987.
22. Avanzolini G., P. Barbini, A. Cappello, G. Cevenini, "Real-time tracking of parameters of lung mechanics: emphasis on algorithm tuning", J. Biomed. Eng., Vol. 12, pp. 489-495, 1990.
23. Lutchen K.R., D. Kaczka, B. Suki, G. Barnas, G. Cevenini, P. Barbini, "Low-frequency respiratory mechanics using ventilator-driven forced oscillations", J. Appl. Physiol., Vol. 75, pp. 2549-2560, 1993.
24. Barbini P., G. Cevenini, K.R. Lutchen, M. Ursino, "Estimating respiratory mechanical parameters of ventilated patients: a critical study in the routine intensive-care unit", Med. Biol. Eng. Comput., Vol. 32, pp. 153-160, 1994.
25. Avanzolini G., P. Barbini, A. Cappello, G. Cevenini, "Influence of flow pattern on the parameter estimates of a simple breathing mechanics model", IEEE Trans. Biomed. Eng., Vol. 42, pp. 394-402, 1995.
26. Avanzolini G., P. Barbini, A. Cappello, G. Cevenini, L. Chiari, "A new approach for tracking respiratory mechanical parameters in real-time", Ann. Biomed. Eng., Vol. 25, pp. 154-163, 1997.
27. D.W. Kaczka, Ingenito EP, Lutchen KR. Technique to determine inspiratory impedance during mechanical ventilation: implications for flow limited patients. Ann Biomed Eng. 1999;27:340-355.
28. Nucci G., M. Mergoni, C. Bricchi, G. Polese, C. Cobelli, A. Rossi, "On-line monitoring of intrinsic PEEP in ventilator-dependent patients", J. Appl. Physiol., Vol. 89, pp. 985-995, 2000.
29. Barbini P., G. Cevenini, F. Bernardi, M.R. Massai, "Comparison of estimates of inspiratory and expiratory resistance and elastance in mechanically ventilated patients", in J. Middleton, M.L. Jones, N.G. Shrive, G.N. Pande "Computer Methods in Biomechanics and Biomedical Engineering - 3", Gordon and Breach Science Publishers, Amsterdam, The Netherlands, pp. 237-242, 2001.
30. Chiari L., G. Avanzolini, M. Ursino, "A comprehensive simulator of the human respiratory system: validation with experimental and simulated data", Ann. Biomed. Eng., vol.25 (1997), 985-999.
31. Brighenti C., G. Gnudi, and G. Avanzolini. A simulation model of the oxygen alveolo-capillary exchange in normal and pathological conditions. Physiological Measurement, 24, 2003, 261-275.
32. R.K. Lambert, "Simulation of the effects of mechanical nonhomogeneities on expiratory flow from human lungs", J. Appl. Physiol. 1990; 68:2550-2563.
33. Artioli E., G. Avanzolini, P. Barbini, G. Cevenini, G. Gnudi, "Classification of postoperative cardiac patients: comparative evaluation of four algorithms", Int. J. Biomed. Comput., vol.29 (1991), 257-270.
34. Ursino M., G. Avanzolini, P. Barbini, "Qualitative simulation of dynamic physiological models using the KEE environment",Artif. Intell. Med., vol.4 (1992), 53-73.
35. Artioli E., G. Avanzolini, P.Barbini, G Gnudi, "A four-parameter linear model for analyzing cardio-respiratory data in post-operative cardiac patients", Med. Eng. & Phys., vol.16 (1994), 484-491.
36. Ursino M., E. Artioli, G. Avanzolini, V. Potuto, "Integration of quantitative and qualitative reasoning: an expert system for cardiosurgical patients". Artif. Intell. Med., vol.6 (1994). 229-247.
37. Artioli E., G. Avanzolini, G. Gnudi, "Extraction of discriminant features in post-cardiosurgical intensive care units", Int. J. Biomed. Comput., vol.39 (1995), 349-358.
38. Ursino M., L.Colì, C. Brighenti, L. Chiari, A. De Pascalis, and G. Avanzolini, "Prediction of solute kinetics, acid-base status, and blood volume changes during profiled hemodialysis, Ann. Biomed. Eng., vol.28 (2000), 204-216.
39. Ursino M., E. Magosso, G. Avanzolini, “An integrated model of the human ventilatory control system: the response to hypercapnia”, Clinical Physiology, Vol. 21: 447-464, 2001.
40. Ursino M., E. Magosso, G. Avanzolini, “An integrated model of the human ventilatory control system: the response to hypoxia”, Clinical Physiology, Vol. 21: 465-477, 2001.
Parole Chiave
BIOINGEGNERIA; MODELLI DEL SISTEMA RESPIRATORIO; MECCANICA RESPIRATORIA; IDENTIFICAZIONE DI SISTEMI FISIOLOGICI; VENTILAZIONE ARTIFICIALE

Bioingegneria del sistema respiratorio

Università degli Studi di Bologna
Abstract
La valutazione quantitativa della meccanica polmonare nei pazienti sottoposti a ventilazione artificiale riveste una ben riconosciuta importanza. Infatti, per conoscere lo stato del paziente e per valutare l'adeguatezza del trattamento terapeutico/ventilatorio è necessario poter quantificare la funzionalità respiratoria complessiva.
In tale contesto, il presente progetto di ricerca ha come obiettivo lo sviluppo di teorie, metodi ed algoritmi atti a migliorare la conoscenza dei meccanismi fisiopatologici della meccanica respiratoria, nonché a favorire il monitoraggio delle principali proprietà viscoelastiche della meccanica respiratoria in soggetti ventilati artificialmente.
In particolare, modelli precedentemente realizzati verranno perfezionati in modo da tenere esplicitamente conto delle modificazioni fisiopatologiche connesse alla broncopneumopatia cronica ostruttiva (Chronic Obstructive Pulmonary Disease, COPD), una patologia con grande impatto socio-economico, essendo diventata oggi la quarta causa di morte nei Paesi Occidentali. Si vuol così realizzare uno strumento di simulazione capace di favorire la comprensione dei meccanismi che producono l'insorgere della flusso limitazione e la sua progressione durante l'evolversi di una patologia ostruttiva. Inoltre, si intendono sviluppare tecniche di stima parametrica utili per monitorare lo stato del paziente e per ottimizzare le scelte ventilatorie.
Il progetto, naturale prosecuzione di un'attività di >>>

Coordinatore Scientifico del Programma di Ricerca
Guido AVANZOLINI Università degli Studi di BOLOGNA
Obiettivo del Programma di Ricerca
Come noto, l'avanzamento delle conoscenze di base sul sistema respiratorio risulta fondamentale per favorire il miglioramento dei processi di diagnosi, di sorveglianza e di terapia. In particolare la valutazione dei parametri della meccanica respiratoria in pazienti sottoposti a trattamento ventilatorio in terapia intensiva costituisce la base di partenza per indicazioni terapeutiche e prognostiche.
Il presente progetto rappresenta la naturale prosecuzione di un'attività di ricerca caratterizzata da un forte impatto internazionale e già finanziata per il biennio 2002-2004 nell'ambito del PRIN.
Obiettivo principale è lo sviluppo di teorie, metodi ed algoritmi atti a migliorare la conoscenza quantitativa della meccanica polmonare in soggetti affetti da broncopneumopatia cronica ostruttiva (Chronic Obstructive Pulmonary Disease, COPD), con una precisa finalizzazione:
(A) comprendere i meccanismi che producono l'insorgere della flusso limitazione e la sua progressione durante l'evolversi di una patologia ostruttiva;
(B) sviluppare tecniche di stima parametrica per il monitoraggio dello stato del paziente e per l'ottimizzazione delle scelte ventilatorie.

Maggiori dettagli sugli obiettivi intermedi della parte (A) e (B) sono dati successivamente in questa stessa sezione.

I pazienti che soffrono di COPD mostrano un progressivo sviluppo della limitazione del flusso espiratorio (Expiratory Flow Limitation, EFL), non del tutto >>>

Durata
24 mesi
Base di partenza scientifica nazionale o internazionale
Le due Unità partecipanti al programma hanno una consolidata esperienza sui temi di ricerca proposti, come illustrato nei Modelli B. Tale esperienza è documentata da numerose pubblicazioni, soprattutto in sede internazionale, in cui sono riportati risultati che costituiscono una solida base di partenza scientifica per questo programma. Inoltre, le stesse unità hanno già collaborato in precedenza a progetti di ricerca sulla "Bioingegneria del sistema respiratorio", anche nell'ambito dei PRIN, dando prova della capacità di coordinare il proprio lavoro e di sfruttare la complementarietà delle diverse conoscenze e risorse per il raggiungimento di un obiettivo comune.
Le competenze delle due Unità di Ricerca sono largamente complementari, pertanto la collaborazione scientifica e l'integrazione fra le due Unità è essenziale per lo svolgimento del presente progetto. In particolare, l'Unità di Bologna sarà il punto di riferimento per lo sviluppo di modelli matematici inversi della meccanica respiratoria, finalizzati all'identificazione parametrica. L'Unità di Siena sarà il principale riferimento clinico, trattandosi di un gruppo misto Clinici-Bioingegneri che opera all'interno di un Dipartimento della Facoltà di Medicina, e parteciperà inoltre, in stretta collaborazione con l'Unità di Bologna, allo sviluppo dei modelli di simulazione della meccanica respiratoria. Le attività delle due unità vanno intese in stretta relazione, apportando ciascuna un contributo indispensabile >>>