Contenuto
Ti trovi in: HOME »Programmi, progetti e risultati »I progetti »PRIN - Programmi di ricerca di Rilevante Interesse Nazionale»Programma di ricerca»Unità di ricercaINIZIO_TESTO_DA_INDICIZZARE
UNITA' DI RICERCA
italiano - english
Bibliografia
1:Poscia A, Messeri D, Moscone D, Ricci F, Valgimigli F.
A novel continuous subcutaneous lactate monitoring system.
Biosens Bioelectron. 2005 May 15;20(11):2244-50.
2:
Poscia A, Mascini M, Moscone D, Luzzana M, Caramenti G, Cremonesi P, Valgimigli F, Bongiovanni C, Varalli M.
A microdialysis technique for continuous subcutaneous glucose monitoring in diabetic patients (part 1).
Biosens Bioelectron. 2003 Jul;18(7):891-8.
3:
Rhemrev-Boom RM, Tiessen RG, Jonker AA, Venema K, Vadgama P, Korf J.
A lightweight measuring device for the continuous in vivo monitoring of glucose by means of ultraslow microdialysis in combination with a miniaturised flow-through biosensor.
Clin Chim Acta. 2002 Feb;316(1-2):1-10.
4:
Varalli M, Marelli G, Maran A, Bistoni S, Luzzana M, Cremonesi P, Caramenti G, Valgimigli F, Poscia A.
A microdialysis technique for continuous subcutaneous glucose monitoring in diabetic patients (part 2).
Biosens Bioelectron. 2003 Jul;18(7):899-905.
5:
Ricci F, Moscone D, Tuta CS, Palleschi G, Amine A, Poscia A, Valgimigli F, Messeri D.
Novel planar glucose biosensors for continuous monitoring use.
Biosens Bioelectron. 2005 Apr 15;20(10):1993-2000.
6:
Korf J, Tiessen RG, Venema K, Rhemrev MM.
[Biosensors for continuous glucose and lactate monitoring]
Ned Tijdschr Geneeskd. 2003 Jun 21;147(25):1204-8. Review. Dutch.
7:
Mo JW, Smart W.
Lactate biosensors for continuous monitoring.
Front Biosci. 2004 Sep 1;9:3384-91.
8:
Leegsma-Vogt G, Rhemrev-Boom MM, Tiessen RG, Venema K, Korf J.
The potential of biosensor technology in clinical monitoring and experimental research.
Biomed Mater Eng. 2004;14(4):455-64.
9:
Palmisano F, Rizzi R, Centonze D, Zambonin PG.
Simultaneous monitoring of glucose and lactate by an interference and cross-talk free dual electrode amperometric biosensor based on electropolymerized thin films.
Biosens Bioelectron. 2000;15(9-10):531-9.
10:
Maran A, Crepaldi C, Tiengo A, Grassi G, Vitali E, Pagano G, Bistoni S, Calabrese G, Santeusanio F, Leonetti F, Ribaudo M, Di Mario U, Annuzzi G, Genovese S, Riccardi G, Previti M, Cucinotta D, Giorgino F, Bellomo A, Giorgino R, Poscia A, Varalli M.
Continuous subcutaneous glucose monitoring in diabetic patients: a multicenter analysis.
Diabetes Care. 2002 Feb;25(2):347-52.
11:
Updike SJ, Shults MC, Gilligan BJ, Rhodes RK.
subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration.
Diabetes Care. 2000 Feb;23(2):208-14.
12:
Wientjes KJ, Grob U, Hattemer A, Hoogenberg K, Jungheim K, Kapitza C, Schoonen AJ; Glucose Monitoring Study Group.
Effects of microdialysis catheter insertion into the subcutaneous adipose tissue assessed by the SCGM1 system.
Diabetes Technol Ther. 2003;5(4):615-20.
13:
Rhemrev-Boom MM, Jonker MA, Venema K, Jobst G, Tiessena R, Korf J.
On-line continuous monitoring of glucose or lactate by ultraslow microdialysis combined with a flow-through nanoliter biosensor based on poly(m-phenylenediamine) ultra-thin polymer membrane as enzyme electrode.
Analyst. 2001 Jul;126(7):1073-9.
14:
Laurell T.
A continuous glucose monitoring system based on microdialysis.
J Med Eng Technol. 1992 Sep-Oct;16(5):187-93.
15:
Gfrerer RJ, Brunner GA, Trajanoski Z, Schaupp L, Sendlhofer G, Skrabal F, Jobst G, Moser I, Urban G, Pieber TR, Wach P.
Novel system for real-time ex vivo lactate monitoring in human whole blood.
Biosens Bioelectron. 1998 Dec 1;13(12):1271-8.
16:
Pfeiffer D, Moller B, Klimes N, Szeponik J, Fischer S.
Amperometric lactate oxidase catheter for real-time lactate monitoring based on thin film technology.
Biosens Bioelectron. 1997;12(6):539-50.
17:
Georganopoulou DG, Carley R, Jones DA, Boutelle MG.
Development and comparison of biosensors for in-vivo applications.
Faraday Discuss. 2000;(116):291-303; discussion 335-51.
18:
Curulli A, Valentini F, Orlanduci S, Terranova ML, Palleschi G.
Pt based enzyme electrode probes assembled with Prussian Blue and conducting polymer nanostructures.
Biosens Bioelectron. 2004 Dec 15;20(6):1223-32.
19:
De Boer J, Korf J, Plijter-Groendijk H.
In vivo monitoring of lactate and glucose with microdialysis and enzyme reactors in intensive care medicine.
Int J Artif Organs. 1994 Mar;17(3):163-70.
20:
Freaney R, McShane A, Keaveny TV, McKenna M, Rabenstein K, Scheller FW, Pfeiffer D, Urban G, Moser I, Jobst G, Manz A, Verpoorte E, Widmer MW, Diamond D, Dempsey E, Saez de Viteri FJ, Smyth M.
Novel instrumentation for real-time monitoring using miniaturized flow systems with integrated biosensors.
1. Amer P. and Bülow J. Assessment of adipose tissue metabolism in man: Comparison of Fick and microdialysis techniques. Clinical Science 85:247-256, 1993.
2.Lafontan M. and Arner P. Application of in situ microdialysis to measure metabolic and vascular responses in adipose tissue. Trends in Pharmacological Science. 17:309313, 1996.
3. Fischer, U., Ertle, R., Abel, P., Rebrin, K., Brunstein, E., Hahn von Dorsche, H. & Freyse, E.J. Assesment of subcutaneous glucose concentration: Validation of the wick technique as a reference for implanted electrochemical sensors in normal and diabetic dogs. Diabetologia 1987; 30, 940-945.
4. Bruckel, J., Kerner, W., Zier, H., Steinbach, G. & Pfeiffer, E.F. In vivo measurement of subcutaneous glucose concentrations with an enzymatic glucose sensor and a wick method.Klin. Wochenschr. 1989; 67, 491-495.
5. Schmidt, F.J., Sluiter, W.J. & Schoonen, A.J.M.Glucose concentration in subcutaneous extracellular space. Diabetes Care 1993; 16, 695-700.Caleidoscopio
6.Stenberg, F., Meyergoff, C., Mennel, F.J., Zier, H. & Pfeiffer, E.F.The function of a hydrogen peroxide detecting electroenzymatic glucose electrode is markedly impaired in human sub-cutaneous tissue and plasma. Biosensors and Bioelectronics 1993; 8, 473-482.
7.Bindra, D.S., Zhang, Y., Wilson, G.S., Stenberg, R., Thévenot, D.R., Moatti, D. & Reach, G. Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring. Anal. Chem. 1991; 63, 1692-1696.
8.Kerner, W., Zier, H., Stembach, G., Bruckel, J., Pfeiffer, E.F., Weiss, T., Camman, K. & Planck, H.A potentially implantable enzyme electrode for amperometric measurement of glucose. Horm. Metabol. Res., Suppl. 1987; 20, 8-13.
9.Moscone, D., Yamanaka, H. & Mascini, M. Biosensors for glucose needle-shaped for in vivo monitoring. Russian Journal of Electrochemistry 1993; 29, 1522-1526.
10.Bugli, M., Moscone, D., Rodinò, P. & Palleschi, G. Construction and evaluation of a needle glucose probe for in vivo monitoring, Clin. Chem. Enzym. Commun. 1995; 7, 17-28.
11. Kissinger PT. Biomedical applications of liquid chromatography-electrochemistry, K. Chromatogr. 1989; 488, 31.
12. Hurd YL, Kehr J, Ungerstedt U. In vivo microdialysis as a technique to monitor drug transport: correlation of extracellular cocaine levels and dopamine overflow in the rat brain. J Neurochem 1988; 51, 1314.
13.Lonnroth P. Jansson PA. Fredholm BB. Smith U.Microdialysis of intercellular adenosime concentration in subcutaneous tissue in humans. Am J Physiol 1989; 256: E250-E255.
14. Moscone D, Mascini M. Microdialysis and glucose biosensor for in vivo monitoring. Ann Biol Clin 1992; 50, 323.
15.Moscone D. and Mascini M. In vivo monitoring with microdialysis probe, in: G.G. Guilbault and M. Mascini (eds.), Uses of Immobilized Biological Compounds, Kluwer, Dordrecht 1993, pp. 115-122
16.Smolenski R.T, Swierczynski J., Narkiewicz M., Zydowo M.M. Purines, lactate and phosphate release from child and adult heart during cardioplegic arrest. Clin. Chim. Acta 1990, 192, 155-164.
17.Karlson J. Muscle exercise, energy metabolism and blood lactate. Adv.Cardiol. 1986, 35, 35-46.
18. Volpe G., Moscone D., Compagnone D., Palleschi G., In vivo continuous monitoring of L-lactate coupling subcutaneous microdialysis and an electrochemical biocell. Sensors and Actuators B 1995, 24-25, 138-141.
19.Palleschi, G., Pizzichini, M., Pilloton, R., Cremisini, C. & Chiavarini, S. (1989) Biosensori: Ricerca, Sviluppo ed applicazioni in campo medico industriale ed ambientale. Enea, Collana Rapporti Tecnici PAS/86/8.
20.Palleschi, G. (1989) Biosensori in medicina. Caleidoscopio, 42, Medical System SpA.
Programma di ricerca
METABOLISMO LOCALE ED ESPRESSIONE GENICA: NUOVE PROSPETTIVE IN CHIRURGIAUniversità di riferimento
Università degli Studi INSUBRIA Varese-Como - SCIENZE CHIRURGICHE - VARESE(VA)Responsabile dell'Unità di ricerca
Gianlorenzo DIONIGIDescrizione
Una prima fase del progetto prevede di mettere a punto un modello sperimentale di chirurgia addominale colo-rettale nel ratto, verificare la possibilità di misurazione dei parametri in studio ( piruvati, lattati, glicerolo, glucosio) a livello di liquido peritoneale prelevato mediante microdialisi.Vengono impiegati per le esperienze ratti Wistar maschi del peso compreso fra 250 e 300 g, stabulati da una settimana e nutriti con pellettato standard (Purina Rat Chow) ed acqua «ad libitum».Gli interventi vengono eseguiti nelle stesse ore predeterminate per evitare alterazioni del ritmo circadiano.
I ratti vengono randomizzati in 6 gruppi (totale 102 ratti), come segue.
Gruppo A:(N=10) controllo per i valori normali: laparotomia mediana, manipolazione delle anse intestinali e dei mesi senza resezione o anastomosi intestinale, posizionamento delle sonde da microdialisi a livello peritoneale e prelievo del liquido interstiziale per 30 minuti per il dosaggio di piruvati, lattati, glicerolo, glucosio e fattori di crescita.
Gruppo B:(N=10) controllo per i valori normali: laparotomia mediana, manipolazione delle anse intestinali e dei mesi senza resezione o anastomosi intestinale, posizionamento delle sonde da microdialisi a livello intestinale mediante punto di ancoraggio in prossimità dell'ansa manipolata sul versante mesenterico e prelievo del liquido interstiziale per 30 minuti per il dosaggio di piruvati, lattati, glicerolo, glucosio e fattori di crescita.
Gruppo C:(N=10) controllo per i valori normali: laparotomia mediana, manipolazione delle anse intestinali e dei mesi senza resezione o anastomosi intestinale, posizionamento delle sonde da microdialisi a livello sottocutaneo e prelievo del liquido interstiziale per 30 minuti per il dosaggio di piruvati, lattati, glicerolo, glucosio e fattori di crescita.
Gruppo D: (N=24) laparotomia mediana, resezione intestinale ed anastomosi e successivo inserimento delle sonde da microdialisi a livello peritoneale. Risveglio degli animali posti in apposita gabbie e prelievo del liquido interstiziale mediante microdialisi per dosaggio di piruvati, lattati, glicerolo, glucosio e fattori di crescita per 24 ore (12 ratti) e 72 ore (12 ratti). Successivo sacrificio degli animali con studio macroscopico e microscopico dell'anastomosi intestinale; identificazione di tratti ischemici, deiscenza di anastomosi.
Gruppo E: (N=24) laparotomia mediana, resezione intestinale ed anastomosi, posizionamento di sonda da microdialisi a livello/in prossimità dell'anastomosi intestinale mediante punto di ancoraggio sull'ansa anastomizzata nel versante mesenterico. Verranno dosati piruvati, lattati, glicerolo, glucosio e fattori di crescita a livello del liquido interstiziale. Risveglio degli animali in apposita gabbia e prelievo del liquido interstiziale mediante microdialisi per dosaggio di piruvati, lattati, glicerolo, glucosio e fattori di crescita per 24 ore (12 ratti) e 73 ore (12 ratti) mediante la sonda inserita. Successivo sacrificio degli animali con studio macroscopico e microscopico dell'anastomosi intestinale; identificazione di tratti ischemici, deiscenza di anastomosi.
Gruppo F: (N=24) laparotomia mediana, resezione intestinale ed anastomosi, posizionamento di sonda da microdialisi a livello sottocutaneo. Verranno dosati piruvati, lattati, glicerolo, glucosio e fattori di crescita a livello del liquido interstiziale. Risveglio degli animali e in apposita gabbia prelievo del liquido interstiziale mediante microdialisi per dosaggio di piruvati, lattati, glicerolo, glucosio e fattori di crescita per 24 ore (12 ratti) e 73 ore (12 ratti). Successivo sacrificio degli animali con studio macroscopico e microscopico dell'anastomosi intestinale; identificazione di tratti ischemici, deiscenza di anastomosi.



